Wire feeder; ROB
5000/ROB 5000
OC
Pin X5/6......... Analog out + 0 to + 10 V
Pin X5/13....... Analog out - (minus)
The wirefeed speed is indicated by a voltage of 0 - 10 V on the analog output
- Actual “wirefeed speed” range .... 0 - Maximum speed
NOTE!
When the power source is idle the „HOLD“ value becomes the wirefeed speed as
soon as the welding operation is complete.
IMPORTANT! The wirefeed speed is calculated from the speed of the motor (rpm).
The wirefeed speed passed to the control may differ from the real speed
- due to slip on the motor feed rollers
Arc length analog
output (ROB
5000/ROB 5000
OC, not active)
Pin X5/5......... Analog out + 0 to + 10 V
Pin X5/12....... Analog out - (minus)
The Arc length analog output (AVC) is used for interfacing to an AVC device (automatic
voltage control).