Example of the use of the ROB 5000 command set for controlling the power source
using analog command values
- 0 - 10 V for welding current
Job selection via the robot:
ROB 5000 ROB 5000 OC
MODE MODE
„0“ „1“ „2“ „0“ „1“ „2“
Job mode 0 1 0 1 0 1
Parameter selection internal 1 1 0 0 0 1
CC / CV 1 0 1 0 1 0
TIG 0 1 1 1 0 0
The ROB 5000/ROB 5000 OC has the following additional digital functions
- Reset error
- Selection of process and operating mode from the robot
- “Touch sensing” function
- “Process active” and main current signals
- External parameters
- “Gas test”, “Wire feed”, “Wire retract”, “Command value switchover” signals
Reset error messages - ROB 5000 / ROB 5000 OC:
Error messages on the power source are reset using the “Source error reset” signal.
However, the cause of the error must first be eliminated.
WARNING!
Danger from surprisingly starting welding process.
This can result in serious injury and damage to property.
If the „Source error reset“ signal is still
24 V ROB 4000/5000 (High)
GND ROB 5000 OC (Low),
the „Welding start“ signal must not be set while the error is being rectified, otherwise
welding will start as soon as the error is fixed.