Check Point : AUXB18LATF
p Check each winding resistance of the motor
If Resistance value is abnormal, replace motor.
117 ± 8%Violet - Blue
117 ± 8%Red - Violet
552 ± 8%Red - Black
White - Red
Read Wire
446 ± 8%
Resistance value(20°C)
Low(Blue)
Med(Violet)
Hi(Red)
(Black)
(White)
(AC)
Thermal protector
(140°C)
Check Point : AUYA20 / 25 / 30LJATF
p Check each winding resistance of the motor
If Resistance value is abnormal, replace motor.
283 ± 8%Violet - Blue
61.2 ± 8%Red - Violet
55.3 ± 8%Red - Black
White - Red
Read Wire
120
±
8%
Resistance value(20°C)
Low(Blue)
Med(Violet)
Hi(Red)
(Black)
(White)
(AC)
Thermal protector
(150°C)
Check Point : AUYA36 / 45 / 54LATF
p Check each winding resistance of the motor
If Resistance value is abnormal, replace motor.
06-100
40.5 ± 10%
Read Wire
44.5 ± 10%
Resistance value(20°C)
(AC)
Thermal protector
130°C
Pr
12
3
1 3
2 3