APPENDIX 3 NOTIFICATION MESSAGES
Code Lvl BDU/Web UI Message Handset Message Explanation/Remedy
0x8056 W Incorrect SIM card
inserted.
Incorrect SIM card
inserted.
The type of USIM card inserted in the terminal
is not correct for your terminal.
For example, an USIM card for a land mobile
system will not work for a maritime system
and vice versa.
0x10208 W All PoE ports except
port 1 are shut down
due to high
temperature.
PoE disabled
on LAN2,3,4
due to high temp.
The temperature in the terminal is too high.
All PoE ports except port 1 are shutdown to
reduce the temperature.
0x11007 E All PoE ports are shut
down due to high
temperature.
All PoE ports are
shut down due to
high temperature.
All PoE ports are shut down due to high
temperature. Restart the Communication Unit.
If the problem persists, contact your dealer.
0x20001109 W NA No Communication
Unit found.
The handset cannot communicate with the
terminal.
0x9114 W Communication error
between
Communication Unit
and ACM in Antenna.
Communication
error between
Comm. Unit and
ACM in Antenna.
Communication error between
Communication Unit and ACM in Antenna.
Check the Antenna cable connection.
0x962A W Communication error
between
Communication Unit
and ACM in Antenna.
Communication
error between
Comm. Unit and
ACM in Antenna.
Communication error between
Communication Unit and ACM in Antenna.
Check the Antenna cable connection.
0x962C W Communication error
between
Communication Unit
and ATR in Antenna.
Communication
error between
Comm. Unit and
ATR in Antenna.
Communication error between
Communication Unit and ATR in Antenna.
Restart the Communication Unit. If the
problem persists, contact your dealer.
0x22600 E No Antenna. No Antenna. No Antenna. Make sure the connection
between Antenna and Communication Unit.
0x10500 W Distress registration
has failed, either
eMLPP registration has
not succeeded, Call
Waiting could not be
enabled or it has taken
too long time in total (5
minutes)
Safety Voice
registration
failed.
Distress registration has failed, either eMLPP
registration has not succeeded, Call Waiting
could not be enabled or it has taken too long
time in total (5 minutes)Contact your SIM
provider and verify eMLPP is enabled on the
SIM card and that Call Waiting service is
commissioned.
0x10501 W Safety voice handset is
not connected.
Safety voice
handset is not
connected.
Safety Voice function is enabled on the
Communication Unit, but unable to detect
Safety Voice handset.
0x10502 W Safety voice settings
are changed.
Safety voice
settings are
changed.
Safety voice settings are changed. Restart
the Communication Unit to enable the
service.
0x10503 W Safety voice settings
are changed.
Safety voice
settings are
changed.
Safety voice settings are changed. Restart
the Communication Unit to disable the
service.
0x10600 W Alarm Panel is not
connected.
Alarm Panel.
is not connected.
Safety Voice function is enabled on the
Communication Unit, but unable to detect
Alarm Panel.
0x10601 W More than one Alarm
Panels are connected.
More than one
Alarm Panels
are connected.
More than one Alarm Panels are connected.
Make sure only one Alarm Panel is
connected.
0x10602 W Distress button error. Distress button
error.
Distress button error. Restart the
Communication Unit and Alarm Panel. If the
problem persists, contact your dealer.
AP-11