15. OTHER FUNCTIONS
15-6
[INSTRUMENTS SETUP] section
[Engine & Tank Manual Setup]:
[Graphic Instruments Setup]:
[Graphic Instruments Setup] - [Maximum Boat Speed], [Maximum Wind Speed]
[Graphic Instruments Setup] - [Depth]
[Graphic Instruments Setup] - [Sea Surface Temperature]
Menu item Description
[Engine & Tank Auto-
matic Setup]
The system will automatically detect engines and tanks connected to the
same network.
[Engine & Tank Manual
Setup]
If the system does not automatically detect engines and tanks, set the en-
gines and tanks manually. See "Engine & Tank Manual Setup" below.
[Graphic Instruments
Setup]
See "Graphic Instruments Setup" below.
[Reset Instrument Pages]: Restore all instrument pages.
[Reset Default Settings]: Restore default settings for the [Graphic In-
struments Setup] menu.
Menu Item Description Options (setting range)
[Nickname] Change the nickname for the engine or tank.
[Used For Propulsion] Select which engine/tank is used to
calculate the distance which may be
traveled using the remaining fuel. [ON] uses
the engine/tank for calculations, [OFF]
ignores the engine/tank.
[OFF], [ON]
[Reset] Resets the engine/tank details to default [OK], [Cancel]
Menu Item Description Options (setting range)
[Maximum Boat Speed] Set the transducer’s maximum detectable
speed.
1 kn to 99 kn
[Maximum Wind Speed] Set the transducer’s maximum detectable
speed.
1 kn to 99 kn
Menu Item Description Options (setting range)
[Minimum Depth] Set the transducer’s minimum detectable
depth.
1 m to 19 m
[Maximum Depth] Set the transducer’s maximum detectable
depth.
20 m to 2000 m
Menu Item Description Options (setting range)
[Minimum Sea Surface
Temperature]
Set the transducer’s minimum detectable
temperature.
0.00°C to 99.99°C
[Maximum Sea Surface
Temperature]
Set the transducer’s maximum detectable
temperature.
0.01 to 99.99°C