NetworX Version 3 Installation Manual
143
5 Battery missing test performed every 12 seconds
6 Manual bell test performed during self-test function (BELL output, I/O and relays)
7 Manual communicator test performed during self-test function
8 Box tamper enabled
Segment 3 (Circle Numbers To Program)
1 Box Tamper report enabled
2 AC Fail report enabled
3 Low Battery report enabled
4 Auxiliary power overcurrent report enabled
5 Siren supervision report enabled
6 Restore Telephone Line Cut report enabled
7 A+B alarm
8 Expander trouble report enabled
Segment 4 (Circle Numbers To Program)
1 Failure To Communicate report enabled
2 Log Full report enabled
3 Autotest report enabled
4 Start and End Programming report enabled
5 End Download report enabled
6 Sensor Low Battery report enabled
7 Sensor Missing report enabled
8 Autotest report enabled ONLY when system is armed
Segment 5 (Circle Numbers To Program)
1 Lost Clock indication enabled
2 Reserved
3 Reserved
4 Enable two trips on the same cross-zone to activate the alarm
5 Disable bypass reports for force armed zones
6 Silent exit. This function also doubles the exit delay (for example, if exit delay is set to 30 seconds, it
changes to 60 seconds).
7 Activate “first disarm reporting” - “last arm reporting” for partitions
8 Automatic switch summer/wintertime and vice versa
Segment 6 (Circle Numbers To Program)
1 Reserved
2 Use internal crystal for clock
3 Enable zone activity in hours (not in days)
4 Enable first alarm logic
5 Enable log protection
6 Disable Clean Me report
7 Siren output is steady in case of fire alarm (BELL output: YES; wireless sirens: NO)
8 User code will reset tamper memory
Segment 7 (Circle Numbers To Program)
1 Dial via GSM when phone line trouble (only when GSM module is enrolled)
2 Exit Error limited to Entry/Exit delay 1
37
1-8
Reserved
38 SWINGER COUNTDOWN COUNT
0
KEYPAD SOUNDER CONTROL
Segment 1 (Circle Numbers To Program)
1 Keypad sounds for Telephone Line Cut when in the Armed state
39
2 Keypad sounds for Telephone Line Cut when in the Disarmed state