EasyManuals Logo
Home>GE>Security System>NetworX V3

GE NetworX V3 User Manual

GE NetworX V3
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #166 background imageLoading...
Page #166 background image
NetworX Version 3 Installation Manual
166
Location Term Definition
3.3.14.2 LED Extinguish
A menu option that enables or disables LED Extinguish
function for an individual keypad. Both options (the one for
a partition an the one for a keypad) must be enabled for
this feature to work. It turns off all status icons on the
keypad (except for the Power icon) after 20 seconds
without a key press. All icons are displayed again when
any key is pressed.
3.3.14.3 Hide PINs A menu option that displays the user code as dashes when
programming codes using the keypad. If this option is
disabled, each digit is shown rather than displayed as a
dash.
3.3.14.4 Beep on RF loss
A menu option that activates the keypad sounder, causing
it to beep, when an RF zone is lost. This beep indicates that
the receiver did not receive the supervision signal from the
wireless transmitter.
On the wired keypad the RF Zone Lost event is signalized
by three beeps every 5 minutes. On the wireless keypad
the RF Zone Lost event is signalized after 15 seconds from
the wake up and then every 5 minutes from the last signal
if the keypad is in the active mode.
3.3.14.5 Always Master Mode A menu option that enables a mode on a master keypad in
which partition status is always displayed regardless of
each partition state.
3.3.14.6 User Phone Editing A menu option that allows the user to change the phone
numbers used for alarm reporting.
Typically, the installer programs the central station phone
numbers and is the only person who can change the
number.
However, when voice protocol and siren protocol are used,
the user can change the phone number. These protocols
typically report to the homeowner’s mobile phone rather
than to the central station.
3.3.14.7 Buzzer On Exit A menu entry that specifies that the keypad should beep
during the exit delay countdown (Exit 1 or Exit 2). Also
System Arming, Leave Now screen displays until the end of
the exit delay time.
Note: This option works for the Arm Away mode only, for
the Arm Stay mode the keypad is always silent. Also see
the Silent Exit Always control panel menu option.
3.3.14.8 Light Control A menu entry that groups X-10 device options for the
selected keypad.
3.3.14.8.1 Unit Code A menu option that sets the X-10 unit code used to identify
a particular X-10 device on the selected module.
3.3.14.8.2 House Code A menu option that sets the code used to identify a
particular premises. It is necessary in case any
neighbouring premises also has an X-10 home automation
system.
More information on the X-10 home automation system
can be found at www.x-10europe.com.
3.3.14.9 Latch Faults until Viewed A menu option that, if enabled, sets the keypad to display

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX V3 and is the answer not in the manual?

GE NetworX V3 Specifications

General IconGeneral
BrandGE
ModelNetworX V3
CategorySecurity System
LanguageEnglish

Related product manuals