page | 201
Advanced Operation
Commands
#set_netmask
Sets the subnet mask for the desired port on the Matrix Controller. The subnet mask
address must be entered using dot-decimal notation. The Matrix Controller must be
rebooted after executing this command. The default net mask is 255.255.255.0.
Syntax
#set_netmask port addr
Parameters
port
Type: INTEGER
Accepts a number from the table below, specifying the desired port.
port Description
1
Control Port (LAN 1)
2
Video Port (LAN 2)
addr
Type: ADDRESS
The subnet mask of the Matrix Controller. This address must be specied
in dot-decimal notation.
Example
#set_netmask 2 255.255.0.0
NETMASK 2 255.255.255.0
Related Commands
#get_gateway
#get_ip_address
#get_ip_mode
#get_ipcong
#get_netmask
#get_web_port
#set_gateway
#set_ip_address
#set_ip_mode
#set_port_mode
#set_web_port