9 TROUBLESHOOTING
9-4
9.4 Error Messages in GP-GL Command Mode
Error
Code
LCD Display Cause Solution
E02001
The plotter received an
unrecognizable command.
Touch the “Conrm” button.
Noise came in when the
computer was turned on.
Congure to drive the plotter
from the menu of the software.
The software conguration
regarding the output device has
been changed.
Reset the interface settings of
the plotter.
The plotter’s interface conditions
have been changed.
Reset the interface settings of
the plotter.
E02004
A command was received
containing numeric parameters
that exceed that command’s
permissible range.
Congure to drive the plotter
from the menu of the software.
The software conguration
regarding the output device has
been changed.
Reset the interface settings of
the software.
The plotter’s interface conditions
have been changed.
Reset the interface settings of
the plotter.
E02005
An error occurred in the receipt
of data within the interface.
Congure to drive the plotter
from the menu of the software.
The software conguration
regarding the output device has
been changed.
Reset the interface settings of
the software.
The plotter’s interface conditions
have been changed.
Reset the interface settings of
the plotter.
E02006
The data out of cutting range has
been received.
Check the data.
Check the size of media and the
cutting range.
Check the magnication setting.
Check the step size (resolution)
settings.