EasyManua.ls Logo

GRAPHTEC CE LITE-50 - Error Messages in HP-GL Command Mode

GRAPHTEC CE LITE-50
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CE LITE-UM-251-9370
9 TROUBLESHOOTING
9-5
9.5 Error Messages in HP-GL Command Mode
Error
Code
LCD Display Cause Solution
E03001
An unrecognizable instruction
was executed.
Execute a recognizable
command.
Execute a command that can be
used.
E03002
A command was executed with
the wrong number of parameters.
Execute the command with a
proper value for the parameter.
E03003
A command containing an
unusable parameter was
specied.
Execute a parameter that can be
used.
E03005
An unrecognizable character set
was specied.
Specify a character set that can
be used.
E03006
The data being input exceeds the
capacity of the plotters cutting
area.
Execute the command with
coordinates within the cutting
area.
E03007
An overow of the buffer memory
has occurred while processing
the downloadable character
buffer or polygon buffer, etc.
Adjust the buffer size.
E03010
Other output command was
executed while executing an
output command.
Check the program.
E03011
An invalid byte was received
after ESC code.
Check the program.
E03012
Invalid byte was received within
device control command.
Check the program.
E03013
A parameter outside of the
permissible range was specied
in the I/O related command.
Check the program.
E03014
Too many parameters in the I/O
related command.
Check the program.

Table of Contents

Other manuals for GRAPHTEC CE LITE-50

Related product manuals