6 DISASSEMBLY AND REASSEMBLY
CE LITE-UM-251-9370 6-82
6.2.34 Carriage Assy
How to detach the carriage assy
(1) Detach the right side cover (See subsection 6.1.1.).
(2) Detach the left side cover (See subsection 6.1.2.).
(3) Detach the cross cut base (See subsection 6.1.4.).
(4) Detach the bottom cover (See subsection 6.1.5.).
(5) Detach the front guide (See subsection 6.1.6.).
(6) Detach the top cover (See subsection 6.1.3.).
(7) Detach the Y-exible cable cover (See subsection 6.2.1.).
(8) Detach the Y-exible cable guard (See subsection 6.2.2.).
(9) Detach the cam board L (See subsection 6.2.11.).
(10) Detach the encoder disk L (See subsection 6.2.13.).
(11) Detach the press cover L (See subsection 6.2.15.).
(12) Detach the X motor (See subsection 6.2.19.).
(13) Detach the X drive pulley (See subsection 6.2.18.).
(14) Detach the press unit L (See subsection 6.2.17.).
(15) Remove the cable from the LED board L.
(16) Remove the M3L6 binding head screw holding the X assy guard on the left side.
M3L6 binding head screw