Safety instructions
Danger
Danger to life through electric shock
y
Insulation monitors can mutually inuence each other.
► Do not connect any other insulation monitors to the
iMAPLA system.
Danger
Danger to life through electric shock
y
With an insulation fault, the “electrical separation” protective
measure - which is otherwise provided by the system - is no
longer eective. This means that - if another fault arises -
potentially fatal contact voltages may arise on metal parts.
y
Second faults for sporadic or sudden load releases may also
arise and lifted material may drop in an uncontrolled fashion.
► Run the system with an insulation fault.
Danger
Danger to life through falling loads!
y
Suspended loads which fall mean an accident risk with danger
to life.
► Never walk or remain under suspended loads.
► Always observe the regulations of the trade association.
► Never switch on the lifting magnet when it is not needed
for the work.
► The machine must be equipped with an emergency power
supply (e.g.backup battery) with abridging time of at
least 10minutes in accordance with DIN EN 13155 “Cranes -
Non-xed load lifting attachments”.
► On mobile systems (e.g.material handling machines),
observe the manufacturer's specications. Nobody is
allowed to remain in the working area/safety area of the
machine during operation.