Page 87 Issue 08/2013
Installation and commissioning
Generator installation for iMAPLA 25and 30
> Secure the drive side of the coupling[4] to the drive and insert it into the
coupling plate. If necessary, while inserting, twist slightly until the gearing
locks.
> Secure the ange[1] to the drive unit.
2a
M12x35
DIN912
4
3
2a
2b
1
4x
2a M12x 35DIN 912
2b
A-12DIN 128
Fig. 31 Assembly of ange mount SAE5 (iMAPLA 25and 30)
5.6.7 Assembly instructions for hydraulic drive
Preparatory disassembly
Ö Fig. 30, Preparatory disassembly of the ange mount SAE5
(iMAPLA25and 30), page86
> Carry out the preparatory disassembly on the generator.
Ö Assembly instructions for ange mount SAE5, page86
Ö Fig. 30, Preparatory disassembly of the ange mount SAE5
(iMAPLA25and 30), page86