Issue 08/2013 Page 56
MAPLA- Modular energy supply system for load lifting magnets
iMAPLA system description
GTS type designation and identication
Danger
Risk of injury and risk of damage!
y
Using switch boxes with ahigher performance class than
the generator is not allowed. Risk of permanent/creeping
overload/overheating of the generator.
Note
2-pole and 4-pole version iMAPLA controllers are only
compatible with the connectors on the appropriate generator.
Note
For test purposes or temporary use, controllers with smaller
output classes can also be connected on larger generators
(provided the connectors are compatible).
The protection functions are always implemented in the
connected switch boxes.
Make sure that the connected lifting magnet is less than the
smallest output gure for the system components (switch box
and generator).