Installation and commissioning
Installation of cables
Requirements for the connection cables between generator and
liftingmagnet
Minimum cross sections
y iMAPLA 8: 5x 4mm² Cu
y iMAPLA 13: 5x 4mm² Cu
y iMAPLA 17: 5x 6mm² Cu
y iMAPLA 20: 5x 6mm² Cu
y iMAPLA 25and 30: 5x 10mm² Cu
y Maximum line length: 30m
Information for Han modular connector cables switch box
liftingmagnet
Note
Only use the Han axial screw-on module in articulated frames.
Features
y 2contact inserts for power circuits
y Contact pin for PE
y Pin insert with additional protective collar
y Polarisation of the module
y Axial screw-on connection system
y For larger external cable diameters incl. isolation, max.10.5mm Ø