COMMAND DETAILS
69
Parameter ON/1, OFF/0 Short Load module
ON/1 Shorting is On
OFF/0 Shorting is Off
Example :LOAD:SHOR: ON
Short circuits the load
module channel.
Query Syntax :LOAD:SHORt[STATe]?
Return Parameter <NR1> Short Load module
1 Shorting is activated
0 Shorting is deactivated
Query Example :LOAD:SHOR?
0
Shorting is deactivated
on the specific channel.
:LOAD:SHORt:KEY
Channel Specific
Command
Description
The SHORT key can be set to Toggle or Hold
mode.
Syntax :LOAD:SHORt:KEY [TOGGLE/1, HOLD/0]
Parameter TOGGLE/1, HOLD/0 Mode
TOGGLE/1 Sets the SHORT key to
toggle mode
HOLD/0 Sets the SHORT key to
hold mode
Example :LOAD:SHOR:KEY 1
Set the SHORT key to
toggle.
Query Syntax :LOAD:SHORt:KEY?
Return Parameter <NR1> Mode
1 Toggle mode is active
0 Hold mode is active
Query Example :LOAD:SHOR:KEY?
0
Hold mode is active for
the specific channel.
PEL-2000 Programming Manual
70
:LOAD:PROTection?
Channel Specific
Command
Description
Returns the protection levels for electronic load
Query Syntax :LOAD:PROTection?
Query Example :LOAD:PROT?
Clears the Channel
Status Register.
Return Parameter <NR1> Condition <NR1> Condition
1 OC 16 OT
2 OV 32 G/N
4 OP 64 UVP
8 RV 16-128 Not Used
Query Example :LOAD:PROT?
0
Returns the status of the
Channel Status Register.
Here 0 is returned
indicating no protection
settings have been
tripped.
:LOAD:PROTection:CLEar
Channel Specific
Command
Description
This command clears the Channel Status Register
for the specific channel. See page131.
Syntax :LOAD:PROTection:CLEar
Example :LOAD:PROT:CLE
Clears the Channel
Status Register.
:LOAD:TIME?
Channel Specific
Command
Description
This command displays the total load on time. If
the load is on, the load time when the command
was issued is displayed.
Query Syntax :LOAD:TIME?