EasyManua.ls Logo

GW Instek PEL-2002 - Program:active; Program:chain; Program:ontime

GW Instek PEL-2002
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMMAND DETAILS
83
SKIP Skip mode: current
program sequence is
skipped.
Example :PROG:SEQ:MODE: AUTO
The current program
sequence is set to
Automatic mode.
Query Syntax :PROGram:SEQuence:MODE? [MANUAL, AUTO,
SKIP]
Return Parameter
[MANUAL, AUTO, SKIP] Current mode
MANUAL Manual mode
AUTO Auto mode
SKIP Skip mode
Query Example :PROG:SEQ:MODE?
AUTO
The current program
sequence is set to AUTO.
:PROGram:ACTive
Program Number
Specific
Description
Activates or selects the active load modules.
Syntax :PROGram:ACTive <NR1>
Parameter
<NR1>
(BIT WEIGHT)
Active
Channel
<NR1>
(BIT WEIGHT)
Active
Channel
1 1 16 5
2 2 32 6
4 3 64 7
8 4 128 8
Example :PROG:ACT 4
Activates channel three.
Query Syntax :PROGram:ACTive? <NR1>
Return Parameter
<NR1>
(BIT WEIGHT)
Active
Channel
<NR1>
(BIT WEIGHT)
Active
Channel
1 1 16 5
2 2 32 6
PEL-2000 Programming Manual
84
4 3 64 7
8 4 128 8
Query Example :PROG:ACT?
12
Channels 3 and 4 are
active.
:PROGram:CHAin
Program Number
Specific
Description
Chains the current program number to a specified
program number.
Syntax :PROGram:CHAin <NR1>
Parameter
<NR1>
Program
1-12 1-12
0 No chain/End chain
Example :PROG:CHA 6
Chains the current
program number to
program number 6
Query Syntax :PROGram:CHAin? <NR1>
Return Parameter
<NR1>
Program
1-12 1-12
0 No chain/End chain
Query Example :PROG:CHA?
6
Returns the program
number the current
program is chained to.
:PROGram:ONTime
Program Number
Specific
Description
Sets the on-time for the program number. 0.1~60
seconds.
Syntax :PROGram:ONTime <NRf>[S]
Parameter
<NRf>[S]
Program On Time
0.1-60 0.1~60 seconds
0.1-60s 0.1~60 seconds