COMMAND DETAILS
83
SKIP Skip mode: current
program sequence is
skipped.
Example :PROG:SEQ:MODE: AUTO
The current program
sequence is set to
Automatic mode.
Query Syntax :PROGram:SEQuence:MODE? [MANUAL, AUTO,
SKIP]
Return Parameter
[MANUAL, AUTO, SKIP] Current mode
MANUAL Manual mode
AUTO Auto mode
SKIP Skip mode
Query Example :PROG:SEQ:MODE?
AUTO
The current program
sequence is set to AUTO.
:PROGram:ACTive
Program Number
Specific
Description
Activates or selects the active load modules.
Syntax :PROGram:ACTive <NR1>
Parameter
<NR1>
(BIT WEIGHT)
Active
Channel
<NR1>
(BIT WEIGHT)
Active
Channel
1 1 16 5
2 2 32 6
4 3 64 7
8 4 128 8
Example :PROG:ACT 4
Activates channel three.
Query Syntax :PROGram:ACTive? <NR1>
Return Parameter
<NR1>
(BIT WEIGHT)
Active
Channel
<NR1>
(BIT WEIGHT)
Active
Channel
1 1 16 5
2 2 32 6
PEL-2000 Programming Manual
84
4 3 64 7
8 4 128 8
Query Example :PROG:ACT?
12
Channels 3 and 4 are
active.
:PROGram:CHAin
Program Number
Specific
Description
Chains the current program number to a specified
program number.
Syntax :PROGram:CHAin <NR1>
Parameter
<NR1>
Program
1-12 1-12
0 No chain/End chain
Example :PROG:CHA 6
Chains the current
program number to
program number 6
Query Syntax :PROGram:CHAin? <NR1>
Return Parameter
<NR1>
Program
1-12 1-12
0 No chain/End chain
Query Example :PROG:CHA?
6
Returns the program
number the current
program is chained to.
:PROGram:ONTime
Program Number
Specific
Description
Sets the on-time for the program number. 0.1~60
seconds.
Syntax :PROGram:ONTime <NRf>[S]
Parameter
<NRf>[S]
Program On Time
0.1-60 0.1~60 seconds
0.1-60s 0.1~60 seconds