COMMAND DETAILS
115
Query Example :VOLT:AVAL?
5
:VOLT:AVAL? MAX
81.6000
A Value is set to 5 volts.
Returns the maximum
settable voltage.
:VOLTage:CURRent
Channel Specific
Command
Description
Sets the current limit in CV mode.
Syntax :VOLTage:CURRent <NRf+>[ A ]
Parameter <NRf+>[ A ] Current limit
1 1 Amp
1A 1 Amp
MIN Sets the current limit to
the minimum value for the
channel
MAX Sets the current limit to
the maximum value for the
channel
Example :VOLT:CURR 1A
Sets the current limit to 1
Amp for the specific
channel.
:VOLT:CURR MAX
Sets the current limit to
the maximum limit for
the specific channel.
Query Syntax :VOLTage:CURRent?
Return Parameter <NR2> 1 unit = 1 amp Current limit
1 Returns the current limit of
the specific channel.
Query Example :VOLT:CURR?
5
The current limit is 5
amps for the specific
channel.
PEL-2000 Programming Manual
116
:VOLTage:MODE
Channel Specific
Command
Description
Set the constant voltage response time for the
specific channel.
Syntax :VOLTage:MODE SLOW/0, FAST/1
Parameter SLOW/0, FAST/1 Response Time
SLOW/0 Slow response time
FAST/1 Fast response time
Example :VOLT:MODE SLOW
Sets the response time to
SLOW for the specific
channel.
:VOLT:MODE 1
Sets the response time to
FAST for the specific
channel.
Query Syntax :VOLTage:MODE? <NR1>
Return Parameter <NR1> Response Time
0 Slow
1 Fast
Query Example :VOLT:MODE?
0
The specific channel is
set to SLOW response
time.