COMMAND DETAILS
75
Query Example :MEAS:ALLV?
2.5000, 3.0000, 0.0000,
0.0000, 0.0000, 0.0000,
5.500, 0.0000
Channel 1 and 2 have
voltages of 2.5 and 3
volts respectively.
Channels 3-6 and 8 have
no voltage and channel
7 is 5.5 volts
:MEASure:ALLCurrent?
All Channel
Command
Description
This query returns the current measured of all the
load modules/channels in order from 1-8 (PEL-
2004)/1-4(PEL2002).
Query Syntax :MEASure:ALLCurrent? <aard>
Query Parameter
<aard> 1 unit = 1 amp
CH1,CH2,CH3,CH4,CH5,
CH6,CH7,CH8
Returns all the current
values from all the
channels, 1-8(PEL-
2004)/1-4(PEL-2002).
Query Example :MEAS:ALLC?
0.0000, 0.0000, 0.0000,
0.0000, 0.0000, 0.0000,
1.2000, 3.5600
Channels 1 to 6 have no
current. Channels 7 & 8
have 1.2 and 3.56 amps,
respectively.
:MEASure:ALLPower?
All Channel
Command
Description
This query returns the power measured of all the
load modules/channels in order from 1-8 (PEL-
2004)/1-4(PEL2002).
Query Syntax :MEASure:ALLPower? <aard>
Query Parameter
<aard> 1 unit = 1 watt
CH1,CH2,CH3,CH4,CH5,
CH6,CH7,CH8
Returns all the power
values from all the
channels, 1-8(PEL-
2004)/1-4(PEL-2002).
PEL-2000 Programming Manual
76
Query Example :MEAS:ALLP?
0.0000, 0.0000, 0.0000
,0.0000, 0.0000, 0.0000,
1.5000, 3.2000
Channels 1 to 6 have no
power. Channels 7 & 8
have 1.5 and 3.2 watts,
respectively.