COMMAND DETAILS
81
Query Example :PROG:MEM?
1
The memory number for
the current
program/sequence is
001.
:PROGram:SEQuence:SHORt:CHANnel
Program Number
Specific
Description
Simulates short circuits for load channels for the
current sequence number.
Syntax :PROGram:SEQuence:SHORt:CHANnel <NR1>
Parameter <NR1>
(BIT WEIGHT)
Channel
number
<NR1>
(BIT WEIGHT)
Channel
number
1 1 16 5
2 2 32 6
4 3 64 7
8 4 128 8
Example :PROG:SEQ:SHOR:CHAN
12
Simulates a short circuit
for channels 3 and 4.
Query Syntax :PROGram:SEQuence:SHORt:CHANnel? <NR1>
Return Parameter <NR1>
(BIT WEIGHT)
Short
Channel
number
<NR1>
(BIT WEIGHT)
Short
Channel
number
1 1 16 5
2 2 32 6
4 3 64 7
8 4 128 8
Query Example :PROG:SEQ:SHOR:CHAN
?
12
Returns channels 3 and 4
are set as shorted for the
program sequence.
PEL-2000 Programming Manual
82
:PROGram:SEQuence:SHORt:TIME
Program Number
Specific
Description
Sets the short time (seconds) for the current
program sequence.
Syntax :PROGram:SEQuence:SHORt:TIME <NRf>[S]
Parameter
<NRf>[S] Short Time
0.1~60 0.1~60 seconds
0.1~60S 0.1~60 seconds
Example :PROG:SEQ:SHOR:TIME
0.5
The short time for the
program sequece is set
to .5 seconds
Query Syntax :PROGram:SEQuence:SHORt:TIME? <NR2>
Return Parameter
<NR2> 1 unit = 1 second Short Time
0.1-60 Returns the short time for
the program sequence.
Query Example :PROG:SEQ:SHOR:TIME?
5
The short time for the
program sequence is 5
seconds.
:PROGram:SEQuence:MODE
Program Number
Specific
Description
Sets the program sequence to Auto, Manual or
Skip mode.
Syntax :PROGram:SEQuence:MODE [MANUAL, AUTO, SKIP]
Parameter
[MANUAL, AUTO, SKIP]
MODE
MANUAL Manual mode: program
sequence is run manually
AUTO Auto mode: program
sequence is run
automatically