Transducer connection
146 A03031_24_E00_01 HBM: public QuantumX
9.26 Encoder and pulse encoder, single-pole
Supported by the following modules: MX840B, MX440B, MX460B
6
10
8
3
Industrial
pulse
encoder
f
2
(+)
Zeroing pulse +
9
4
7
2
5
5 V
3.5 V
1.5 V
Thresholds
Thresholds
f
1
Signal single-pole, schematic diagram
0 V
f
1
(+)
Hsg.
Cable shield
Hsg. = Housing
6
1
123
1
5
6
10
11
15
2 Data
3 No function
1
Adjustable sensor supply: Pin12: 5 V ... 24 V
Pin 11: 0 V
1-wire EEPROM (optional)
view from below
Maximum input voltage: 5 V to ground