Continuous output/HBM protocol (Cont.out)
WTX110 A4774-1.0 HBM: public 197
WTX110 as a remote indication
This data set is used for extended output to a WTX110 as a remote indication.
For WTX110 remote indication, Remote Display mode must be set.
Pressing of the Tare and Zero keys on the WTX110 (remote indication) is
returned to the transmitter (the WTX110 weighing terminal), and corresponds
to the same key press on the transmitter.
14.2 Customized protocol
The data set is freely configurable. In the following table, x and y are place
holders. If the condition is met, the character specified under x is displayed.
If the condition is not met, the letter R specified under y is displayed instead.
Example: MB:R = in motion a B is displayed, otherwise an R.
Entry of the colon with the suffixed character y is optional. If the entry is not
made, a blank is left if the condition is not met.
Example: M~ = in motion the tilde character is displayed, otherwise a blank.
Weights are transferred with decimal points as separators. Unoccupied (lead
ing positions are filled by blanks.
String Sent Example
Mx:y Sends the character specified under x if the scale
is in motion, e.g. B, otherwise the character
specified under y.
MB:R
mx:y Sends the character specified under x if the scale
is stable, e.g.: R, , otherwise the character
specified under y.
mR:~
Ox:y Sends the character specified under x if the scale
is overloaded, e.g.: U, otherwise the character
specified under y.
OU:N
ox:y Sends the character specified under x if the scale
is not overloaded, e.g.: U, otherwise the character
specified under y.
oN:U