Service mode
WTX110 A4774-1.0 HBM: public 81
6.4.2 Configure digital I/Os (Config. Digital IO)
Menu Key Function/Secondary selection
Config. Digital IO
PIM Digital inputs/outputs in slot PIM1
Modbus TCP To control external I/O modules via
Ethernet, WTX110 works as the
Modbus TCP master
SIO Digital inputs and outputs in slot
SIM1
None Not used
Modbus TCP selected
IP Enter the IP address for the local network
6.4.3 Configure analog outputs (Configuration Analog out)
Information
If the selected WTX110 variant has an analog output, DAU15 must always be
selected for the analog output.