Calibration
WTX110 A4774-1.0 HBM: public 181
Function/Secondary selectionKeyMenu
Onscreen typeplate? Y Select whether the Onscreen typeplate will be
displayed above the scale display:
Y Display typeplate
N Hide; the field is left blank
Update Rate 225 Select the update rate for the digital filter
50 800 Hz Setting range
225 Hz Default setting
If there are vibrations around the scale, the
properties of the digital filter can be optimized
here. The update rate should be selected as far
away as possible from the vibration frequency
and from the multiple of the vibration frequency.
11.9 Incline Setup
The optical tilt sensor is selected in group Adaptation\Incline
Switch\Sensor.
Information
If In 0 to In 7 is selected there is a discrete prompt of an external optical tilt
sensor and no correction is made.
If sensor is selected there is a correction of the weight value or a discrete
prompt.