Quick Reference Guide
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
13841 Rev A
xiii
After First Time Startup, Balance Run No. 1
Make sure the proper model is selected at the Choose A/C
Model screen, then press START.
Select the Component, Flight Regime and Change Type to
be used for balance, then press START.
Select Measurement Sensor. The default EV2K+ balance
channel can be changed, if desired. AutoCorrection
may also be toggled to <ON >. Press START.
Operate the component at the desired balance RPM. When
the RPM is steady, press START.
When the Vibrex unit has finished collecting data, press
START.
Press START to view the solution.
Apply changes exactly as specified or use ALTERNATE
SOLUTION to view other solution options.
Press Done (Next Run/Job) if balance is acceptable,
otherwise ensure the proper solution (change) type is
selected and press START.
Implement the solution and power off the Vibrex unit.
After Balance Run No. 1
Turn on the Vibrex unit.
Select Helicopter Balance (or Fixed Wing
Balance) from the Main Menu screen.
Select the component and <Continue Job> then press
START.
Operate the helicopter/aircraft at the same RPM as done in
Run No. 1. When the RPM is steady, press START.
When the Vibrex unit has finished collecting data, press
START.
Continue making adjustments until the component yields the
desired IPS level, then press DONE from the Aircraft
Balance Quality screen.