Chapter 5 – General Operation
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
13841 Rev A
138
NOTE: The TRK DATA signal from magnetic pickup
channel B is a relative number representing the blade track
pulses coming in from the FasTrak
®
. The magnitude of
these numbers can change based upon the blade height
deviations and rotor speed. It may vary slightly as blade
track height varies. It is presented mainly to insure that
stable track pulses are being received. If this number is
zero, check the FasTrak
®
connections. If it varies widely,
check sun position into the FasTrak
®
lens or the condition
of the paint on the blades.
10. Press the START key. An acquiring screen will appear
briefly as the FasTrak
®
acquires required number of
rotational data pulses.
11. Upon successful acquisition, a screen similar to the
following will appear:
FasTrak® Power On
Allow to Stabilize
480 RPM (CH A)
7530 TRK DATA(CH B)
When RPM is steady
push START