8-16 SCSI and I/O
1 = HP A3058A 1Gbyte Disk
2 = HP DDS Products (All)
3 = HP F/W SCSI Disks (HP A3145A)
4 = Wangtek 1.2 Gbyte QIC Tape Drive (HPA2944A)
5 = Exabyte 8 mm Tape (HP A3024A)
6 = CD-ROM (HP A3086A & HP A3184A)
50 01 Write Failure after Retry Limit Reached 5
51 00 Erase Failure 2, 4
52 00 Cartridge Fault 2, 4
53 00 Media Load/Eject Failed 2, 4
53 01 Unload Tape Failure 4
53 02 Medium Removal Prevented 2, 4
57 00 Unable to Recover Table-Of-Contents 6
5A 00 Operator Request or State Change Input (Unspecified) 6
5A 01 Operator Requested Media Removal 5
5B 00 Log Exception (Segate Factory Installed Option) 1
5B 01 Threshold Condition Met (Segate Factory Installed Option) 1
5B 01 Log Threshold Met (sense key 6) 5
5B 02 Log counter At Maximum (Segate Factory Installed Option) 1
5B 02 Log Parameter Overflow (sense key 1) 5
5B 03 Log List Codes EXAUSTED (Segate Factory Installed Option) 1
5C 00 RPL Status Change 1
63 00 End of User Area Encountered on This Track 6
64 00 Illegal Mode for this Track 6
70 XX Vendor Specified (See Appropriate Product Documentation)
80 00 General Firmware Error Qualifier 1
81 00 Mode Mismatch Fixed/Variable (sense key 5) 5
82 00 No Tape Required but Tape Loaded (SEND DIAGNOSTIC) (sense key 5) 5
82 80 Humidity too High
82 81 Dryness, Humidity falls to a level that permits access
82 82 Device Requires Cleaning 2
82 83 Bad Microcode Detected 2
84 00 Could not Change Mode Parameters since tape not at LBOT or LBOP (sense key 5) 5
NOTE
Even Though the listed Additional Sense Codes and Qualifiers are sometimes listed as associated to a
particular device, other devices may return the same values with the same meaning. Some devices
may also have vendor unique codes which are not listed.
Table 8-10 Hardware Status Bytes 12 and 13
ASC ASCQ Description Notes