If the test message is not received at the E-mail address, check the E-mail server set tings.
SNMP notication
To receive VLS n
otication alerts on a management console (s), you must edit the SNMP settings to specify
the management console(s) you want to receive VLS SNMP traps.
Editing the SNMP settin gs
NOTE:
To display VLS notication alerts on a management console, the management console must be running
HP Systems Insight Manager, and be c ongured to receive SNMP traps from the VLS.
To add a management console(s) to the SNMP aler t distribution list:
1. Log in to Command View VLS as the administrator. See Opening a Command View VLS session
from Command View TL.
2. Click the Notications tab .
The Notication s window displays (Figure 66).
3. Click Edit SNMP Setting in the task bar.
The Edit SNMP Settings window opens (Figure 69).
Figure 69 Edit SNMP Settings window
4. To add management consoles:
a. Enter the host name of a management console that you want to receive VLS SNMP traps in
the Hostname box.
b. Enter the string name that is passed with the set to get commands from the management console
in the Community String box.
This value is typically set to Public.
c. Select the appropriate trap version for the management application that will receive the SNMP
traps in the Trap Version box.
Select 1 for the trap version if your management application is HP Systems Insight Manager.
d. Click Add.
e. To add another management console, repeat these steps.
104 Monitoring