11148
5
10 11
1 2 3 4
6789
1
Dual port FC ca
rd, host port, port 0
2
Dual port FC card, host port, port 1
3
Dual port FC card, stora ge port, port 3
4
Dual port FC card, stora ge port, port 2
5
Serial port to access CLI
6
Monitor and keyboard
7
NIC1, on pri
mary node only connects to the customer-provided external network (array)
8
NIC2, on primar y node connects to port 1 of switch 2824
9
USB por t, connects to USB/Ethernet adapter, then to port 1 of switch 2524
10
Power supply 2
11
Power supply 1
Figure 8 Primary node ports
a. Connect one end of an Ethernet cable (not included) to NIC1. Connect the other end of the
cable to t
he existing external network.
b. Connect
one end of an FC cable (not provided) to host port 0. Connect the other end to an
external FC switch/fabric that connects to your tape backup hosts.
c. If desired, connect one end of an FC cable (not provided) to host por t 1. Connect the other end
to an ext
ernal FC switch/fabric that connects to your tape backup hosts. Otherwise, conne ct a
loopback plug to host port 1.
d. Connect one end of an FC cable (not provided) to d evice por t 3. Connect the other end to an
external FC switch/fabric that connects to your external array.
e. Connec
t one end of an FC cable (not provided) to device port 2. Connect the other end to a
second external FC switch/fabric that connects to your external array.
f. Connecttotheserialport(cableisprovided)toaccessthecommand-lineuserinterfaceatinitial
config
uration. Also connect to this during debug activities. Disconnect from this port during
normal operations.
NOTE:
You must connect to the keyboard and monitor ports when performing Quick Restore
(keyboard and monitor not included).
g. Connect one end of an Ethernet cable to NIC2. Connect the other end of the cable to port
1 of Switch 2824 (see Figure 1 0).
h. Connect one end of a USB cable to the USB port. Connect the other end of the cable to the
USB/Ethernet adapter. Connect an Ethernet cable to the Ethernet end of the adapter, then
connect the Ethernet cable to port 1 of Switch 2524 (see Figure 11).
i. Connect a power cable to each power supply and to a PDU. If possible, connect each power
supply to a separate PDU to provide redundancy.
HP StorageWorks
31