Figure 56 Fix Primary Paths Wizard window
6. Select Apply to set all paths back to their primary paths.
Failure of both paths (double path failure) is indicated by the red critical icon and a specicnotica tion
message. The notic a tion message differs based on whether the failure oc curs while running or upon
booting the system (Figure 57).
Figure 57 Notica tions window
A double path failure that occurs while running results in the critical aler t Fibre Chann el Paths
Failed for Lun, ulid <numerical LUN id number> wwnn <numerical wwnn>.
A double path failure that occurs upon booting the system results in the critical alert Missing
Storage LUN paths on node #.
This means the node can not communicate with the LUN at all. If the failed paths are on the primary
node, the whole storage pool containing that LUN is off-line; if the failed paths are on a secondary node,
the storage pool is on-line until reboot, but the storage pool is inaccessible from that node. In this case,
you can still get to the LUNs, but only from a different node.
To repair double path failure (assuming there has been no reboot during the failure):
1. Determine the cause of the failures and repair them if needed.
2. In Command View VLS, access the System tab.