WARNING!
To reduce the risk of electric shock or damage to the equipment, do not connect the power cord to the
power supply until the power supply is installed.
1. Removetheprotectivecoverfromtheconnectorpinsonthepowersupply.
2. Slide the power supply into the bay until it clicks.
Figure 76 Installin g an AC power supply
3. Use the strain relief clip to secure the power cord (Figure 77).
Figure 77 Placin g th e power cord in the strain relief clip
4. Connect the power cord to the power supply.
5. Be sure that the power supply LED is green.
Power supply zone fan module
CAUTION:
Do not operate the node for long periods without the access panel. Operating the node without the
access panel results in improper airow and improper cooling that can lead to thermal damage.
1. Power off the node. See Powering off the system.
2. Extend or remove the node from the rack. See Extending the node from the rack.
3. Remove the access panel. See Removing the VLS node access panel.
4. Remove the SATA cable from the cable clip to avoid damaging the cable.