Table 46 Error codes (part code 5205) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WThe volume of Delta resync cannot be
specified as a migration target.
See "Supported and prohibited source
and target volumes" in the HP
StorageWorks P9000 Performance for
Open and Mainframe Systems User
Guide.
The volume specified as a migration
target is used as a volume of Delta
resync for Continuous Access Journal or
Continuous Access Journal Z.
555995205
WThe volume of Delta resync cannot be
specified as a reserved volume.
See "Supported and prohibited source
and target volumes" in the HP
StorageWorks P9000 Performance for
Open and Mainframe Systems User
Guide.
The specified volume is used as a volume
of Delta resync for Continuous Access
Journal or Continuous Access Journal Z.
556005205
WSpecify the volumes with the same cache
mode.
Migration between external volumes with
different cache modes is invalid.
556465205
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
563015205
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
563025205
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
563035205
EAn error occurred during processing. If
this problem persists, please contact HP
Technical Support.
This function cannot be used by the
storage partition administrator.
565245205
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
571015205
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
571025205
WIf the problem persists despite retrying,
please contact HP Technical Support.
The disk subsystem is in internal process.
Please retry the operation.
584515205
EIf this problem persists, please contact
HP Technical Support.
An error occurred on the DKC side.585725205
ECheck if the DKCMAIN microcode and
SVP microcode versions are mismatched.
This function is not supported.585735205
EIf this problem persists, please contact
HP Technical Support.
An error occurred while connecting to
the subsystem.
585745205
EIf this problem persists, please contact
HP Technical Support.
An error occurred while connecting to
the subsystem.
585755205
EIf this problem persists, please contact
HP Technical Support.
A communication time-out error occurred
in the disk subsystem.
585765205
WSpecify another volume.The specified volume(s) are the leaf
volume(s) of Business Copy.
654345205
WCheck the setting of the specified volume.The specified volume(s) are already
being used as of Thin Provisioning
volume (V-VOL) (s).
656735205
126 Message (part code group 5nnn)