EasyManua.ls Logo

HP StorageWorks P9000 - Disk Arrays

HP StorageWorks P9000 - Disk Arrays
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 50 Error codes (part code 6005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
EPlease contact HP Technical Support.The attribute of the port assigned to
SLPRs except SLPR0 can only be changed
to Target.
552306005
EPlease contact HP Technical Support.This function cannot be used by the
storage partition administrator.
565246005
EIf the problem persists despite retrying,
please contact HP Technical Support.
An error occurred during SVP
processing.
570056005
WSelect another volume, and retry the
operation.
A pair cannot be created because the
specified M-VOL is used by Continuous
Access Journal or Continuous Access
Journal Z.
583196005
WIf the Add Pair (Paircreate) operation
failed:
When the RCU runs on the 2DC
configuration in which the Continuous
Access Journal cooperates, wait for
a while until the pair status of the
Continuous Access Journal becomes
“PAIR, then retry the operation.
When the RCU runs on the
configuration other than the 2DC
configuration in which the Continuous
Access Journal cooperates, specify
another volume for R-VOL, then retry
the operation.
If the Pairresync operation failed, resume
the Continuous Access Journal pair
volume first.
The operation failed because the
specified R-VOL was used by Continuous
Access Journal or Continuous Access
Journal Z.
583206005
WSelect another volume and retry the
operation.
The pair cannot be created because the
specified M-VOL is a LUSE volume that
is set across multiple CLPRs.
583216005
WSelect another volume, and retry the
operation.
The pair cannot be created because the
specified R-VOL is a LUSE volume that is
set across the multiple CLPRs.
583226005
WCheck to ensure that you did not
mistakenly attempt to create a volume
with or without VMA.
A pair cannot be created, because you
tried to create a volume pair formed with
a volume to which VMA is set by Data
Retention and a volume without VMA.
583576005
WWait a while, then retry the operation.A pair cannot be created, because the
set processing of VMA that is used for
Data Retention has not been completed
for the specified P-VOL.
583586005
WWait a while, then retry the operation.A pair cannot be created, because the
set processing of VMA that is used for
Data Retention has not been completed
for the specified S-VOL.
583596005
WIf the problem persists despite retrying,
please contact HP Technical Support.
The disk subsystem is in internal process.
Please retry the operation.
584516005
Part code 6005 151