Table 50 Error codes (part code 6005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck whether the number of the
specified R-VOL is correct or the status
of the usage of the host to the specified
R-VOL.
The operation failed because the host
did not allow the specified R-VOL to be
used as an R-VOL.
585866005
WCheck whether the version of DKC
microcode of RCU supports the 4x4x4
cascade function. If the version does not
support the 4x4x4 cascade function,
update the microcode of RCU to the
version that supports the function, or retry
the Add Pair operation with the setting
that does not transfer Time Stamp.
The Add Pair operation failed.
The volume pair cannot be created with
Time Stamp set, because RCU does not
support 4x4x4 cascade function.
586406005
WCheck the licensed capacity of these
program products.
See the user's guides of Continuous
Access Synchronous or Continuous
Access Synchronous Z for details of the
licensed capacities.
The licensed capacity of Continuous
Access Synchronous or Continuous
Access Synchronous Z on the RCU is
insufficient.
587126005
WCheck the licensed capacity of these
program products.
See the user's guides of Continuous
Access Synchronous or Continuous
Access Synchronous Z for details of the
licensed capacities.
The licensed capacity of Continuous
Access Synchronous or Continuous
Access Synchronous Z on the MCU is
insufficient.
587146005
WCheck if the configuration changing
process by RAID Manager, Auto LUN,
or Quick Restore is not in the operation,
then retry the operation.
The configuration changing processes
are conflicting at DKC.
657406005
WCheck whether the specified R-VOL is a
Thin Provisioning volume.
The operation failed because the
specified M-VOL was used as a Thin
Provisioning volume.
680116005
WCheck whether the specified R-VOL is a
Thin Provisioning volume.
The operation failed because the
specified R-VOL was used as a Thin
Provisioning volume.
680126005
WConfirm that no pairs are in COPY or
Pending status, then retry the operation.
"Maximum Initial Copy Activities (CU)"
cannot be changed to Enable or Disable,
because there are pairs in COPY or
Pending status.
680206005
WInstall Disaster Recovery Extended
function to the MCU.
The specified M-VOL is used as a data
volume of Continuous Access Journal or
Continuous Access Journal Z. The
operation failed because Disaster
Recovery Extended function is not
installed in the MCU.
680226005
WInstall Disaster Recovery Extended
function to the RCU.
The specified R-VOL is used as a data
volume of Continuous Access Journal or
Continuous Access Journal Z. The
operation failed because Disaster
Recovery Extended function is not
installed in the RCU.
680236005
Part code 6005 153

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Related product manuals