Page #154 background image
Table 50 Error codes (part code 6005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the CU number, the LDKC
number, or the LU number of the
specified M-VOL.
The operation failed because the RCU
does not support the CU number, the
LDKC number or the LU number of the
specified M-VOL.
680276005
WSelect another volume that is not used
by other program products such as
Business Copy/Snapshot, and Auto LUN,
or cancel the use of the volume operated
by other program products, and retry the
operation.
The Paircreate operation has failed
because the specified S-VOL, which is a
Thin Provisioning volume, is already used
by another program product.
687576005
WCheck whether the specified R-VOL is a
System Disk.
The Add Pair(Paircreate) operation failed
because the specified R-VOL was a
System Disk.
687586005
WCheck whether the specified R-VOL is a
System Disk.
The Add Pair(Paircreate) operation failed
because the specified M-VOL was a
System Disk.
687646005
WInstall the Continuous Access
Synchronous function to the storage
system.
The operation failed because the
Continuous Access Synchronous function
was not installed.
687876005
WInstall the Continuous Access
Synchronous function to the RCU.
The Paircreate operation failed because
the Continuous Access Synchronous
function was not installed in the RCU.
687896005
WRefresh the window, and confirm
whether the specified volume is an
R-VOL.
The operation failed because the
specified volume was not an R-VOL.
687916005
WRefresh the window, and confirm
whether the status of the specified volume
is SSWS.
The Reverse Resync operation failed
because the status of the specified
volume was not SSWS.
687936005
WCreate a path from the RCU to the MCU.The operation failed because the path
from the RCU to the MCU did not exist.
687946005
EContact the Support Center, and check
the shared memory.
The operation failed. The shared memory
might be insufficient.
Please contact HP Technical Support.
687956005
WRefresh the window, and confirm the pair
status of the specified volume.
The operation failed. The operation
cannot be accepted in the pair status of
the specified volume.
687966005
WCheck each capacity of the M-VOL and
the R-VOL after the capacity change of
R-VOL ends, and plan a combination of
volumes for pair creating.
A pair could not be created because the
specified R-VOL was a Thin Provisioning
volume whose capacity was being
changed.
688126005
WCheck each capacity of the M-VOL and
the R-VOL after the capacity change of
M-VOL ends, and plan a combination of
volumes for pair creating.
A pair could not be created because the
specified M-VOL was a Thin Provisioning
volume whose capacity was being
changed.
688136005
WThe specified volume is a primary data
volume of the Continuous Access Journal,
which runs on the 2DC configuration in
which the Continuous Access
Synchronous cooperates. Specify another
volume.
A pair cannot be created because the
specified volume is used as a primary
data volume of the Continuous Access
Journal.
688166005
154 Message (part code group 6nnn)

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
Form FactorRack-mountable
ModelHP StorageWorks P9000
TypeDisk Array
CategoryStorage
Drive TypeSSD, SAS
RAID LevelsRAID 0, 1, 5, 6, 10
Host InterfaceFibre Channel, FCoE, iSCSI
ConnectivityFibre Channel, FCoE, iSCSI
Cache MemoryUp to 512 GB
ControllersDual controllers
Management SoftwareHP StorageWorks Command View
Redundancycontrollers, power supplies, and fans
Operating Humidity20 to 80% relative humidity, non-condensing