Table 52 Error codes (part code 6010) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WRegister some RCUs of CU Free, then
retry the operation.
There are no RCUs available. Register
some RCUs of CU Free, then retry the
operation.
657706010
WCreate some external volumes, then retry
the operation.
There are no external volumes that can
be used as a quorum disk. Create some
external volumes, then retry the
operation.
657716010
WAssign another external volume not used
in the quorum disk IDs, then retry the
operation.
An external volume is assigned to two
or more quorum disk IDs. An external
volume cannot be used for multiple
quorum disk IDs.
657726010
WSelect a RCU and a quorum disk ID that
have the same serial number and the
controller ID, then retry the operation.
The serial number and the controller ID
of the RCU registered in a quorum disk
do not correspond with the specified
RCU.
657736010
WSelect the quorum disk ID corresponding
with the serial number and the controller
ID of the RCU that which is used by the
specified pair, then retry the operation.
The serial number and the controller ID
of the RCU registered in a quorum disk
do not correspond with the information
of RCU used by the specified pair.
657746010
WCheck the LDKC number for the specified
data volume, and specify only one LDKC
number.
There are two or more LDKC numbers
for the specified data volume. In this
operation, please specify only one LDKC
number.
690186010
WRegister RCUs in the CU or RCUs of CU
Free, then retry the operation.
There are no RCUs available. Register
RCUs in the CU or RCUs of CU Free,
then retry the operation.
690226010
WTo create pairs that have different CU
numbers coexisting in the pair, register
RCU of CU Free and retry the operation.
To crate pairs with RCU in the CU, select
the M-VOLs so that different CU numbers
do not coexist in the M-VOLs, and retry
the operation.
There are no RUCs available.
To create pairs that have different CU
numbers coexisting in the pair, register
RCU of CU Free and retry the operation.
To create pairs with RCU in the CU,
select the M-VOLs so that different CU
numbers do not coexist in the M-VOLs,
and retry the operation.
690236010
WClick [OK]. Apply the Preview data to
the disk storage system, then retry the
operation.
Since the number of preview data
exceeded the maximum, the excess data
were discarded. No more preview data
can be stored.
690336010
WClick [OK]. Apply the Preview data to
the disk storage system, then retry the
operation.
The number of preview data exceeds the
maximum.
No more preview data can be stored.
690346010
WSelect M-VOLs so that different CU
numbers do not coexist in the M-VOLs,
and retry the operation.
Different CU numbers coexist in the
selected M-VOLs. Select M-VOLs so that
different CU numbers do not coexist in
the M-VOLs, and retry the operation.
690356010
WChange the number of characters used
for the file name to less than 32, then
retry operation.
The file name should be from 1 to 32
characters.
690366010
WDelete the unnecessary script files, then
retry the operation.
More than 256 script files cannot be
transferred to the SVP.
690376010
164 Message (part code group 6nnn)

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals