Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WIf you are performing a path operation,
retry the operation after the FREEZE
status is released.
If you are performing a pair operation,
check the DKC status, wait until the SCP
time elapses, then retry the operation.
The operation was rejected due to a
'FREEZE' state.
87126505
WExchange the port type after deleting the
group setting.
The port group already exists on the
specified port.
87136505
EPlease contact HP Technical Support.An internal error occurred.87146505
WEnsure that the number of paths is
correct, then retry the operation. If the
problem persists, please contact HP
Technical Support.
The number of paths is incorrect.87156505
WCheck the serial number and the
controller ID of this remote storage
system and already registered remote
storage systems, then specify the correct
values.
If the specified values are correct, check
the cable connection of the remote
storage system. If the problem persists,
please contact HP Technical Support.
The serial number or the controller ID of
the remote subsystem is incorrect.
87196505
WReduce the number of registered remote
storage systems, then retry the operation.
The number of registered remote
subsystems already reached the
maximum (that is, 64).
87206505
WCheck the path connections between the
local and the remote storage systems,
then retry the operation.
Path creation has not finished yet.87216505
WCheck the path connections between the
local and the remote storage systems,
then retry the operation.
Path creation failed.87226505
WAdd another path, or delete all pairs on
the remote storage system. Then retry the
operation.
The Edit Path operation was rejected
because the specified path is the last
path of some Remote Copy pairs.
87236505
WCheck the number of paths.The specified number of paths is less
than the minimum number specified in
the DKC Option window.
87246505
WDo either of the following to recover from
the error:
• If the error code is 100c, add normal
paths, then set the minimum number
of paths.
• If the error code is 100d, add normal
paths, then delete paths. Alternatively,
reduce the minimum number of paths,
then delete paths.
The number of minimum paths exceeds
the number of normal paths.
87276505
Part code 6505 167