Loading...
Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the status of the pinned tracks in
the primary data volume, and clear the
pinned tracks.
Pinned track(s) exists in the primary data
volume.
87426505
WCheck the status of the pinned tracks in
the secondary data volume, and clear
the pinned tracks.
Pinned track(s) exists in the secondary
data volume.
87436505
WCheck whether the primary data volume
is in any of the following conditions:
Data in the primary data volume is
being copied; correction copy or
drive copy is in progress.
The primary data volume is in
correction access condition.
The primary data volume is blocked.
The primary data volume is being
maintained.
The access attribute of the primary
data volume is Read Only.
The specified primary data volume
cannot be used.
87446505
WCheck whether the secondary data
volume in the remote storage system,
which are connected from hosts or the
SVP, is in any of the following
conditions:
The secondary data volume is being
used by Dual Copy.
The secondary data volume is being
used by XRC Replication.
The secondary data volume is being
used by PPRC or Remote Copy.
The secondary data volume is being
used by Concurrent Copy.
The access attribute of the secondary
data volume is Read Only.
The secondary data volume is already
in use by another system.
87456505
WSee the INSTALLATION SECTION and
the OPENPLATFORM SECTION in the
maintenance manual to check if the
device emulation of the primary data
volume is supported.
The emulation type of the primary data
volume is not supported by Continuous
Access Journal or Continuous Access
Journal Z.
87466505
WCheck if the secondary data volume is
online. If the secondary data volume is
online, vary the volume offline, then retry
the operation. If the secondary data
volume is connected to a VM system,
vary the volume offline from the VM
system.
The specified secondary data volume is
online.
87496505
ECheck the SSB log, then contact HP
Technical Support.
An internal error occurred.87536505
ECheck the status of the cache and the
shared memory in the primary storage
system.
Ensure that the cache and shared
memory is not blocked.
One side of the cache or the shared
memory is blocked in the primary
storage system.
87576505
Part code 6505 169