Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the attribute of the specified
journal.
Journals cannot be added to the
extended consistency group (EXCTG),
because the attribute of the specified
journal is invalid.
586216505
WCheck if the specified command device
exists in the device of specified serial
number.
Journals cannot be added to the
extended consistency group (EXCTG),
because the combination of the serial
number and the command device is
invalid.
586246505
WCheck if the specified journal is being
used by other program product you are
using.
Journals cannot be added to the
extended consistency group (EXCTG),
because the specified journals are being
used by another program product.
586256505
WCheck the status of the command device.The specified operation failed because
the command device was not registered
or has been blocked.
586276505
WCheck the attribute of the journals in the
specified extended consistency group
(EXCTG).
Journals cannot be added to the
specified extended consistency group
(EXCTG), because different journal
attributes coexist in the EXCTG.
586286505
WIf this problem persists please contact HP
Technical Support.
The specified operation failed because
of a temporary path failure. Retry the
operation. If this problem persists, please
contact HP Technical Support.
586296505
WConfirm whether the specified volume is
set by Cache Residency or Cache
Residency Z.
The specified volume cannot be used as
a journal volume because the volume is
set by Cache Residency or Cache
Residency Z.
586416505
WCheck the DKCMAIN microcode version
of the secondary storage system, and
contact HP Technical Support to confirm
whether the Continuous Access Journal
or the Continuous Access Journal Z
function supports the Delta resync
function.
The operation failed because the
Continuous Access Journal or the
Continuous Access Journal Z function of
the secondary storage system does not
support the Delta resync function.
586836505
WCheck the status of the primary data
volume in the Continuous Access
Synchronous window or the Continuous
Access Synchronous Z window.
The operation to change the status to the
status ready for Delta resync failed.
The specified primary data volume
should meet the following requirements.
• The specified volume is a secondary
data volume for Continuous Access
Synchronous or Continuous Access
Synchronous Z.
• The pair status of Continuous Access
Synchronous or Continuous Access
Synchronous Z is PAIR or Duplex.
586846505
190 Message (part code group 6nnn)