Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the following of the specified
primary data volume.
The volume is an M-VOL of a
synchronous pair, and the pair status
is in PAIR or Duplex when it is
referenced from the Continuous
Access Synchronous window, the
Continuous Access Synchronous Z
window, the RAID Manager, or the
Business Continuity Manager.
The volume is an R-VOL of a
synchronous pair, and the pair status
is in SSWS or Swapping when it is
referenced from the RAID Manager
or Business Continuity Manager.
Delta resync operation failed because
the specified primary data volume was
not a data volume of Continuous Access
Synchronous or Continuous Access
Synchronous Z, or the pair status of the
primary data volume was invalid.
586856505
WCheck the attribute of the journal of the
remote storage system.
The specified operation failed, because
the attribute of the journal of the remote
storage system was not "restore."
586866505
WIf the problem persists despite retrying,
contact HP Technical Support.
The status of the other mirror of the Delta
resync did not change.
586876505
WCheck the status of the specified primary
data volume.
Delta resync failed because the specified
primary data volume was not ready for
Delta resync.
586886505
WCheck the status of the mirrors in the
specified journal.
The operation failed, because the status
of some mirrors in the master or restore
journal was invalid. Check the status of
the mirrors in the specified journal.
586896505
WCheck the status on the primary data
volume.
The recovery to the status ready for Delta
resync failed, because the status of the
specified primary data volume was one
of the following:
The primary data volume is being
copied; correction copy or drive copy
is in progress.
The primary data volume is in
correction access status.
The primary data volume is blocked
The primary data volume is being
maintained.
The access attribute of the primary
data volume is Read Only.
586906505
WSpecify another mirror ID.The specified mirror ID is already used
in the restore journal.
Specify another mirror ID.
586916505
WCheck the status of the master journal.The specified master journal cannot be
used for Delta resync, because it is
registered in the extended consistency
group (EXCTG).
586926505
WCheck the status of the restore journal.The specified restore journal cannot be
used for Delta resync, because it is
registered in the extended consistency
group (EXCTG).
586936505
Part code 6505 191