Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WInstall the Disaster Recovery Extended
function in the primary storage system.
The specified primary data volume is
used as a pair volume of Continuous
Access Synchronous or Continuous
Access Synchronous Z. The operation
failed because the Disaster Recovery
Extended function was not installed in
the primary storage system.
680256505
WInstall the Disaster Recovery Extended
function in the secondary storage system.
The specified secondary data volume is
used as a pair volume of Continuous
Access Synchronous or Continuous
Access Synchronous Z. The operation
failed because the Disaster Recovery
Extended function was not installed in
the secondary storage system.
680266505
WConfirm the LDKC number of the
specified extended consistency group.
Journals cannot be added to the
extended consistency group(EXCTG),
because the current microcode version
does not support LDKC numbers other
than 0.
680286505
WCheck whether the LDEV number or LUN,
and mirror ID of the specified volume are
correct.
The status of the specified volume is
Simplex or SMPL.
Check whether the LDEV number or LUN,
and mirror ID of the specified volume are
correct.
687596505
WCheck whether the specified primary
data volume is a System Disk.
The Add Pair(Paircreate) operation failed
because the specified primary data
volume was a System Disk.
687786505
WCheck whether the specified primary
data volume is a System Disk.
The Add Pair(Paircreate) operation failed
because the specified secondary data
volume was a System Disk.
687796505
WCheck whether the specified primary
data volume is a System Disk.
The specified volume cannot be used as
a journal volume because it is a System
Disk.
687806505
WThe specified master journal runs on the
2DC configuration in which the
Continuous Access Synchronous
cooperates.
Specify "Mirror" for the Error Level.
The specified operation failed, because
"LU" was specified for the Error Level.
Please specify "Mirror" for the Error
Level, and retry the operation.
687816505
WThe specified master journal group runs
on the 2DC configuration in which the
Continuous Access Synchronous
cooperates.
Specify other than "0" for the Mirror ID,
then retry the operation.
The Paircreate operation failed because
"0" was specified for the Mirror ID.
Please specify other than 0 for the Mirror
ID, and retry the operation.
687826505
WThe specified master journal group runs
on the 2DC configuration in which the
Continuous Access Synchronous
cooperates.
Delete the Continuous Access
Synchronous pair, and retry the
operation, or specify the volume that is
not used by the Continuous Access
Synchronous.
The Paircreate operation failed because
the specified primary data volume was
used by Continuous Access Synchronous.
687836505
200 Message (part code group 6nnn)