Table 55 Error codes (part code 6510) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WSpecify a mirror ID other than 0.Specify a mirror ID other than "0" if you
create a pair ready for Delta resync.
593266510
WCheck the status of the specified master
journal.
You cannot specify [Entire] or [None] to
the Initial copy mode under the current
status of the specified master journal.
Check the status of the specified master
journal.
593276510
WChange the status of mirror of the journal
to "Initial," then retry the operation.
The journal volume cannot be deleted,
because the attribute of mirror for the
journal is "master" and the status of the
mirror is "Hold" or "Holding."
593286510
WClick the check box when you add the
journal of the local DKC to the extended
consistency group (EXCTG).
The serial number of the local DKC is
entered. Select the check box when you
add the journal of the local DKC to the
extended consistency group (EXCTG).
593296510
WDelete the entered DKC to use the journal
of the local DKC.
The local DKC cannot be specified for
the extended consistency group (EXCTG),
because the serial number other than the
local DKC is entered.
Delete the entered DKC to use the journal
of the local DKC.
593306510
WCheck whether the specified volume is
a LUSE volume. Also, check storage
system’s microcode version.
A LUSE volume is included in the
specified volumes.
The current version of the microcode
does not allow you to create pairs using
LUSE volumes.
593316510
WCheck the value of the path watch time.The value of the path watch time is not
entered or is outside the range. Check
the value of the path watch time.
593356510
WSpecify another volume.The specified volume is not valid for this
program product. Specify another
volume.
656646510
WCheck the monitoring setting.The specified volume is not the volume
to be monitored. Check the monitoring
setting.
656656510
WThe microcode versions between the
DKCMAIN and the SVP might not match.
Confirm the microcode versions of the
DKCMAIN and the SVP.
The current microcode version of
DKCMAIN cannot assign remote
command devices to mirrors.
657776510
WCheck if a remote command device was
assigned to the specified mirror.
No more remote command devices can
be assigned to the specified mirror.
657786510
WCheck if the specified journals include
mirrors available to assign a remote
command device.
There are no mirrors available to assign
a remote command device.
657796510
WSpecify different mirror IDs in the mirror
1 and the mirror 2 parameters.
The same mirror ID is specified in the
mirror 1 and the mirror 2 parameters.
657806510
iTo stop the operation, click [OK].
To continue the operation, click [Cancel].
Are you sure you want to cancel the
export?
690166510
210 Message (part code group 6nnn)

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals