Table 55 Error codes (part code 6510) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WUse the sort function to identify volumes
with the same LDKC number, the same
CU number and the same LDEV number.
The same volume is stored more than
once in the Preview list.
Please use the sort function to identify
volumes with the same LDKC number,
the same CU number and the same LDEV
number.
591006510
WCreate a volume that can be used as a
journal volume. To do this, add a volume
or use some other way.
There is no volume that can be registered
or deleted.
591036510
WSpecify another parity group.The specified parity group does not
contain volumes that can be registered
or deleted as journal volumes.
591046510
WCheck the CLPR number for the specified
data volume, and specify only one CLPR
number.
There are two or more CLPR numbers for
the specified data volume. In this
operation, please specify only one CLPR
number.
591116510
WSpecify only the volume that has the
same CLPR number as the CLPR number
of the volume in the Preview list.
The CLPR number of the specified data
volume is different from the CLPR number
of the data volume in the Preview list. In
this operation, please specify only one
CLPR number.
591126510
WCheck the CLPR number of the specified
volume and the CLPR numbers of volumes
if it is already existed. Specify a volume
so that there is only one CLPR number in
the journal.
Multiple CLPR numbers are existing in
the specified volume, or you tried to
register a volume different from the CLPR
number of an existing volume. In one
journal, more than one CLPR numbers
cannot be existed.
591136510
WCheck the amount of the Preview data.
If the amount of the Preview data is too
large, clear the Preview data by clicking
[Apply], and retry the operation.
If the amount of Preview data is small or
there is no Preview data, too much data
is selected. Reduce the number of data,
and retry the operation.
The number of Preview data may have
exceeded the limit, or too large number
of data is selected.
591156510
WCheck the microcode version of the
DKCMAIN, then contact HP Technical
Support.
The specified function is not supported
by the current microcode version.
591166510
WChange the mirror status of the journal
to Stop or Initial, then retry the operation.
The journal volume cannot be deleted,
because the mirror status of the journal
is Active.
591536510
WCheck the number of journals in the
specified extended consistency group
(EXCTG).
No more journal can be added to the
specified extended consistency group
(EXCTG).
593216510
WCheck the entered parameter.The entered parameter is invalid. The
serial number, the LDKC number, or the
journal to be added is not specified.
593236510
WCheck the status of the specified master
journal.
A pair which is ready for Delta resync
cannot be created under the current
status of the specified master journal.
Check the status of the specified master
journal.
593256510
Part code 6510 209