Table 56 Error codes (part code 6610) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the CLPR number of the specified
volume and the CLPR numbers of volumes
if it is already existed. Specify a volume
so that there is only one CLPR number in
the journal.
Multiple CLPR numbers are existing in
the specified volume, or you tried to
register a volume different from the CLPR
number of an existing volume. In one
journal, more than one CLPR numbers
cannot be existed.
591136610
WCheck the amount of the Preview data.
If the amount of the Preview data is too
large, clear the Preview data by clicking
[Apply], and then retry the operation.
If the amount of Preview data is small or
there is no Preview data, too much data
is selected. Reduce the number of data,
and retry the operation.
The number of Preview data may have
exceeded the limit, or too large number
of data is selected.
591156610
WCheck the microcode version of the
DKCMAIN, then contact HP Technical
Support.
The specified function is not supported
by the current microcode version.
591166610
WCheck the microcode version of
DKCMAIN. To use other emulation types,
please contact HP Technical Support to
update the microcode version of
DKCMAIN.
The current microcode version of
DKCMAIN does not support Add Pair
(Paircreate) operations, Resume Pair
operations, and Change Pair Option
operations using the emulation type of
the specified volume.
591506610
WTo use a mainframe volume as a journal
volume, please contact HP Technical
Support to update the microcode version
of DKCMAIN.
The current microcode version of
DKCMAIN only supports OPEN-V as the
emulation type of a journal volume.
591516610
WCheck the emulation type of the specified
volume.
There are two or more kinds of emulation
types that cannot be combined, in the
specified volume. Or you tried to add a
volume which cannot be combined with
the emulation type of the existing volume.
591526610
WChange the mirror status of the journal
to Stop or Initial, then retry the operation.
The journal volume cannot be deleted,
because the mirror status of the journal
is Active.
591536610
WCheck the number of journals in the
specified extended consistency group
(EXCTG).
No more journal can be added to the
specified extended consistency group
(EXCTG).
593216610
WCheck whether all extended consistency
groups (EXCTG) are used by other
program products.
There are no valid extended consistency
groups (EXCTG).
593226610
WCheck the entered parameter.The entered parameter is invalid. The
serial number, the LDKC number, or the
journal to be added is not specified.
593236610
WCheck if the specified journals include
the journals which belong to an extended
consistency group (EXCTG).
Some of the specified journals belong to
an extended consistency group (EXCTG).
The timer type for journals which belong
to EXCTG must be "System.”
593246610
WCheck the status of the specified master
journal.
A pair which is ready for Delta resync
cannot be created under the current
status of the specified master journal.
Check the status of the specified master
journal.
593256610
Part code 6610 217