Table 65 Error codes (part code 8105) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WThe configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
WWN number, which is not registered,
is specified. (When deleting, or
changing.)
10668105
WThe configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
You are trying to register the same host
group as the existing one.
10678105
WThe configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
The specified host group has not been
registered.
10688105
WCheck the setting, then retry the
operation.
The following volumes cannot be
specified when you change the
command device configurations:
Volumes reserved by Auto LUN
Volumes other than the open-system
volumes (including unmounted
volumes)
System Disk volume
11088105
WRemove the prohibited characters from
the nickname.
You cannot use following characters for
the name:
" \ / : , ; * ? < > |
You cannot use spaces for the first and
the last characters in the name.
11108105
WCheck the setting(s), then retry the
operation.
When requesting a configuration change
of LUN-Security, a nickname is not
specified. Specify the nickname of HOST
GROUP.
11118105
WCheck the setting(s), then retry the
operation.
When registering WWN, the value is
not specified. Or, zero is set as the value
of WWN. Be sure to set the WWN
value before requesting the configuration
change.
11168105
WThe configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
Command device security cannot be set
to the specified volume because the
volume is not a command device.
11238105
WThe setting method of command
device/command device security is
incorrect. The following settings are
invalid. *Set command device + Release
command device security
*Release command device + Set
command device security
The error does not occur normally
because it cannot be modified in the
window. In the unlikely event that this
error occurs, please contact HP Technical
Support.
An error occurred. If this problem
persists, please contact HP Technical
Support.
The command device setting and the
command device security setting are
incorrect. You cannot do any of the
following to the same volume:
Specify the volume as a command
device and disable command device
security on the volume.
Specify the volume as a
non-command device and enable
command device security on the
volume.
11248105
Part code 8105 261

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals