Table 65 Error codes (part code 8105) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCorrect the name of the group.The group cannot be added. Change
the name of the group.
57478105
WCorrect the group ID.The group ID does not exist.57488105
WCorrect the group ID.The same group ID is already registered.57498105
WCorrect the group name.The same group name is already
registered.
57508105
WCorrect the group ID.The group ID does not exist.57518105
WCorrect the group name.The group name does not exist.57528105
WCorrect the port ID and the group ID.There is a difference between the current
port ID/group ID and the specified one.
57538105
WCorrect the CU and LDEV.The intermediate volume cannot be
specified as a command device.
57548105
WTurn on the security switch on this port.The security switch on the port remains
off. Turn the switch on.
57558105
WAdd the WWN to another port.The number of WWN cannot exceed
255 per port.
57568105
WCorrect the WWN.The same WWN is already registered.57578105
WCorrect the group ID.No name can be added to the group ID
(00).
57588105
WCorrect the name.The same name is already registered.57598105
WCorrect the WWN.The WWN does not exist.57618105
WCorrect the name.The name does not exist.57628105
WAdd the LUN to another group or
another port.
The number of LUN cannot exceed 512
per port or 256 per host group.
57648105
WCorrect the LUN.The LUN is already used.57658105
WCorrect the CU and LDEV.The specified CU:LDEV is invalid.57668105
WCorrect the LUN.The LUN does not exist.57678105
WCorrect the LUN.There is a difference between the current
LUN and the specified LUN.
57688105
WCorrect the group ID.The group cannot be added.57698105
WSet the port attribute to target in
advance.
The port cannot be changed because the
port is an initiator port.
57708105
WThe PCB mode value is invalid. Specify
a correct value.
The setting cannot be performed,
because an invalid PCB mode is set to
the specified CHA.
57718105
WCorrect the CU and LDEV.The system LU cannot be used.57858105
WCorrect the name of port.The path can be defined only for the A,
E, J or N port.
57868105
WCorrect the CU and LDEV.The intermediate volume cannot be
specified as a command device.
57898105
WIf nothing changes despite retrying,
please contact HP Technical Support.
A program error occurred under internal
process.
57908105
Part code 8105 267