Table 71 Error codes (part code 8505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
60128505
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
60228505
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
60248505
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
71108505
WIf this problem persists, please contact
HP Technical Support to reboot the SVP
PC.
A communication time-out error occurred.80018505
EIf the same problem persists despite
retrying, please contact HP Technical
Support.
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
80028505
ECheck the status of the storage system
(for example, the storage system is
blocked, the shared memory is
inconsistent, or some other problem
occurs). If this problem persists, please
contact HP Technical Support.
The status of the disk subsystem requires
maintenance (for example, the subsystem
is blocked, the shared memory is
inconsistent, or some other factor). Please
contact HP Technical Support.
84018505
EPlease contact HP Technical Support.The current microcode does not support
the partitioning of the resources used by
the program products (SLPR Key). Check
the microcode version and the supported
specifications and then correct the
settings.
550088505
WCorrect the CLPR No., then retry the
operation. If this problem persists, please
contact HP Technical Support.
An invalid CLPR No. was detected.550098505
EPlease contact HP Technical Support.An invalid SLPR No. was detected.550108505
WCorrect the CLPR Name, then retry the
operation. If this problem persists, please
contact HP Technical Support.
An invalid CLPR name was detected.
CLPR No:%s
550118505
EPlease contact HP Technical Support.An invalid SLPR Name was detected.
SLPR No:%s
550128505
WPlease contact HP Technical Support.Invalid login information was detected.
SLPR No:%s
550138505
WAssign a different CLPR name, then retry
the operation. If this problem persists,
please contact HP Technical Support.
This name is already being used as the
CLPR name.
CLPR No:%s
CLPR No:%s
550148505
EPlease contact HP Technical Support.This name is already being used as the
SLPR name.
SLPR No:%s
SLPR No:%s
550158505
Part code 8505 271

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
Form FactorRack-mountable
ModelHP StorageWorks P9000
TypeDisk Array
CategoryStorage
Drive TypeSSD, SAS
RAID LevelsRAID 0, 1, 5, 6, 10
Host InterfaceFibre Channel, FCoE, iSCSI
ConnectivityFibre Channel, FCoE, iSCSI
Cache MemoryUp to 512 GB
ControllersDual controllers
Management SoftwareHP StorageWorks Command View
Redundancycontrollers, power supplies, and fans
Operating Humidity20 to 80% relative humidity, non-condensing