Table 93 Error codes (part code 20123) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
ELog in again.A network error occurred. It is not
possible to connect with the SVP because
a timeout error occurred while
communicating with the SVP.
10701820123
EIf this problem persists, please contact
HP Technical Support.
Failed to restore the user account list file.10701920123
WInstall a supported version of JRE, then
retry the operation.
An unsupported version of JRE is used.10702020123
ERefresh the window, then retry the
operation. If the same problem persists
despite retrying, please contact HP
Technical Support.
An internal logic error occurred.10702120123
ERefresh the window, then retry the
operation. If the same problem persists
despite retrying, please contact HP
Technical Support.
An internal logic error occurred.10702220123
EClick [Refresh All] on the [File] menu,
then retry the operation. If the same
problem persists despite retrying, please
contact HP Technical Support.
An internal logic error occurred.10702320123
EIf the same problem persists despite
retrying, please contact HP Technical
Support.
The content of a task to be registered
conflicts with that of another that has
already been registered. Retry the
operation.
10702420123
WWait for a while, then retry the
operation.
The operation failed, because the
configuration information was being
changed.
10702520123
WWait, then retry the refreshing operation.The operation failed because the storage
system performed refreshing internally.
10702620123
WWait, then retry the refreshing operation.The refreshing operation wan not
completed because the configuration
was changing.
10702720123
EYou cannot connect to the SVP because
of factors, such as a network error or
SVP error. Check the IP address. If the
IP address is correct, close the browser
(also close the browser of the storage
list), and log in again after waiting a
while. If the problem persists, please
contact HP Technical Support. The
version of Remote Web Console may not
match the version of destination SVP.
Clear the cache of JRE and the browser.
Restart the browser, and then retry the
processing. The Remote Web Console
is downloaded via the network and then
executed. If you use a proxy server, the
old version of the program may remain
in the cache of the proxy, and may be
downloaded and executed. If this
problem persists, contact your network
administrator. If your network does not
have any problem, and this problem
persists, please contact HP Technical
Support.
A network error occurred. The causes
might be one of the following.
The SVP was not ready.
An error occurred in the SVP.
A timeout error occurred while
communicating with the SVP.
10702820123
306 Message (part code group 20nnn)

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers: