Table 21 Error codes (part code 0605) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the setting of CacheMode.CacheMode is invalid.667220605
WCheck the setting of InflowControl.InflowControl is invalid.667240605
WCheck the setting of LDKC.It is not set within the range where LDKC
can be used.
667360605
WCheck the setting of CU.It is not set within the range where CU
can be used.
667390605
WCheck the setting of LDEV.It is not set within the range where LDEV
can be used.
667420605
WCheck the setting of LDEV capacity.It is not set within the range where LDEV
capacity can be used.
667440605
WCheck the setting of SSID.A value different from SSID that has
already been set is specified.
667480605
WCheck the setting of path.The number of paths has reached the
maximum number.
667490605
WCheck the specified WWN.The specified WWN is not registered.667500605
WExcluding the overlapping setting, then
retry the operation.
The specified WWN has already been
specified.
667510605
WCheck the type of the storage system.The specified external volume is a
volume of the storage system that cannot
be used as an external storage.
667520605
WCheck the setting of SSID.The value of SSID is not set within the
available range.
667470605
WCheck the specified WWN.Specified WWN was not found.667980605
WCheck the specified external volume.Specified external volume was not found.667990605
WDelete all the pairs and the Pools that
belong to Snapshot Pool-VOL, then retry
the operation.
The Snapshot Pool-VOL is included in the
items.
687300605
WDelete the Thin Provisioning Pool in
which the volume included in the items
to be maintained is registered, then retry
the operation.
The volumes registered in a Thin
Provisioning Pool are included in the
items to be maintained.
687330605
WRestore the blocked status of the system
disk. If the status cannot be restored,
please contact HP Technical Support.
A volume used as system disk is included
in the items to be maintained.
687350605
WChange the status of the associated Thin
Provisioning volume to blocked, then
retry the operation.
The Disconnect External Storage Systems
or the Disconnect External Volumes
cannot be executed for an external
volume that includes Pool VOLs
registered in the pool that has the
association with a normal Thin
Provisioning volume.
687410605
WIf there is a volume whose cache mode
cannot be changed due to its bind mode
setting, release the bind mode setting
first.
Set the same cache mode to all the
volumes that compose a Pool VOL.
687420605
WWait for the migrating volume or the
Quick Restore to be completed, then retry
the operation.
Volume migration or Quick Restore is in
progress.
688000605
Part code 0605 47

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals