[Sysname-wlan-st-service1] client-security intrusion-protection action temporary-block
[Sysname-wlan-st-service1] client-security intrusion-protection timer temporary-block
120
Related commands
client-security intrusion-protection action
client-security intrusion-protection enable
client-security intrusion-protection timer
temporary-service-stop
Use client-security intrusion-protection timer temporary-service-stop to set the BSS silence
period for intrusion protection.
Use undo client-security intrusion-protection timer temporary-service-stop to restore the
default.
Syntax
client-security intrusion-protection timer temporary-service-stop time
undo client-security intrusion-protection timer temporary-service-stop
Default
The BSS silence period for intrusion protection is 20 seconds.
Views
Service template view
Predefined user roles
network-admin
Parameters
time: Specifies the period during which a BSS is disabled. The value range is 10 to 300 seconds.
Usage guidelines
This command takes effect only when the intrusion protection action is temporary-service-stop.
If you change the BSS silence period after the service template is enabled, the new setting takes
effect on the subsequent detected illegal packets.
Examples
# Set the BSS silence period to 30 seconds for intrusion protection on service template service1.
<Sysname> system-view
[Sysname] wlan service-template service1
[Sysname-wlan-st-service1] client-security intrusion-protection enable
[Sysname-wlan-st-service1] client-security intrusion-protection action
temporary-service-stop
[Sysname-wlan-st-service1] client-security intrusion-protection timer
temporary-service-stop 30
Related commands
client-security intrusion-protection action
client-security intrusion-protection enable